7-123
7-3-11 E-Cam Parameteres (EC9□□)
EC901 E-Cam function selection
【
5-6-15
】
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 2 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
1330H -- -- O -- -- -- --
Setting Description:
Setting Description
0 No
1 Flying shear function
2
Rotary cut function
EC902.0 E-Cam main axle feedback source
【
5-6-15
】
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 1 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0802H -- -- O -- -- -- --
Setting Description:
Setting Description
0 Physical
1 Virtual
EC902.2 If E-Cam uses return to origin
【
5-6-15
】
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 1 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0802H -- -- O -- -- -- --
Setting Description:
Setting Description
0 Usage
1 Not Used