EasyManua.ls Logo

TECO JSDG2S Series - 9-1 Error Alarm List

TECO JSDG2S Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-2
9-1 Error Alarm List
Error Alarm
Number
Error Alarm Description
603F
h
Error code
3001
h
Error Code
Alarm Clearing
Method
AL.000 No Alarm Currently 0x0000
AL.001 Power Supply Voltage Too Low 0x3220-04-0001 Cn031.1
AL.002 Power Supply Voltage Too High 0x3210-04-0002 Switch Reset
AL.003 Motor Overload 0x3230-02-0003 Switch Reset
AL.004 Driver Over Current 0x2310-02-0004 Power Re-set
AL.005 Encoder Signal Error 0x7305-01-0005 Power Re-set
AL.007
Multifunction Contact Planning
Error
0x5441-01-0007 Power Re-set
AL.008 Parameter Data Read/Write Error 0x5500-01-0008 Switch Reset
AL.009 Emergency Stop 0x5442-01-0009 Cn002.3
AL.010
Absolute Type Encoder Battery
Warning
0x7305-01-0010 Switch Reset
AL.011 Excessive Position Error 0x8611-01-0011 Switch Reset
AL.012 Motor Over Speed 0x8400-01-0012 Switch Reset
AL.013 Motor Model Number Error 0x6320-01-0013 Power Re-set
AL.014 Drive Prohibit Error 0x5443-01-0014 Switch Reset
AL.015 Driver Overheat 0x4210-08-0015 Switch Reset
AL.016
Absolute Type Encoder Number of
Revolution Error
0x7305-01-0016 Switch Reset
AL.017 MCU Error 1 0x6100-80-0017 Power Re-set
AL.018 MCU Error 2 0x6100-80-0018 Power Re-set
AL.019 MCU Error 3 0x6100-80-0019 Power Re-set
AL.020 Motor Wire Disconnection Error 0xff03-80-0020 Power Re-set
AL.021
Communication type Encoder
Error
0x7305-01-0021 Power Re-set
AL.022
Excessive Error between motor
and load
0x8611-01-0022 Switch Reset
AL.023 E-Cam Function Error 0x6320-01-0023 Power Re-set
AL.025
Driver Voltage Class Switching
Error (200/400V)
0x6320-01-0025 Power Re-set
AL.026
Full-closed Loop ABZ Phase
Signal Error
0x7305-01-0026 Power Re-set