5-45
5-4-1 External Pulse Command Mode
The Pulse Command in this Mode is provided by an external device there are three pulse patterns
can be selected, each pulse pattern can also be programmed as positive or negative logic. The user sets
the corresponding pattern based on the External Input Pulse Command pattern. The setting method is
as follows:
Pn301.0 Position pulse command pattern selection
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 3 Power Re-set 0301H
Setting Description:
Setting Description
0 Pulse+Sign
1 CCW+CW Pulse
2 A phase+ B phase pulse * 2
3 A phase+ B phase pulse * 4
Setting Description: Can select Filter Smoothing Time.
Position Pulse
Command
Pattern
Positive Logic Negative Logic
CCW Command CW Command CCW Command CW Command
Pulse +
Sign
CCW+
CW/Pulse
Phase A+
Phase B
Pulse