EasyManua.ls Logo

TECO JSDG2S Series - Page 665

TECO JSDG2S Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-4
Error Alarm
Number
Error Alarm Description
603F
h
Error code
3001
h
Error Code
Alarm Clearing
Method
Error
AL.051 Motor overload 0x3230-02-0051 Switch reset
AL.052 External sensor over-temperature 0x4210-08-0052 Switch reset
AL.053 EtherCAT WDT abnormal 0xff00-80-0053 Switch reset
AL.054
EtherCAT CSP, IP position
command incremental error
0xff00-80-0054 Switch reset
AL.055
Pulse encoder UVW signal
abnormal
0x7305-01-0055 Switch reset
AL.056
Pulse encoder ABZ signal
abnormal
0x7305-01-0056 Switch reset
AL.057 Speed S curve setting error 0x6320-80-0057 Switch reset
AL.058 Electronic gear ratio setting error 0x6320-80-0058 Switch reset
AL.059
EtherCAT synchronization
manager configuration error
0xff00-80-0059 Switch reset
AL.060
EtherCAT synchronization signal
abnormal
0xff00-80-0060 Switch reset
AL.061
Regenerative parameter setting
error
0x6320-80-0061 Switch reset
AL.062 Servo excitation instruction invalid 0xff04-80-0062 Switch reset
AL.063
Map parameter address (MAb
group) parameter setting error
0x6320-80-0063
Reset
Reset parameter
AL.064 Software limit setting error 0x6320-80-0064 Switch reset
AL.065 Turret alarm 1 0x6320-80-0065 Switch reset
AL.066 Turret alarm 2 0x6320-80-0066 Switch reset
AL.067 Turret alarm 3 0x6320-80-0067 Switch reset
AL.068 Turret alarm 4 0x6320-80-0068 Switch reset
AL.069 Turret alarm 5 0x6320-80-0069 Switch reset
AL.070 Turret alarm 6 0x6320-80-0070 Switch reset
AL.071 Turret alarm 7 0x6320-80-0071 Switch reset
AL.072
EtherCAT/CANopen ControlWord
input error
0x6320-80-0072 Switch reset
AL.073
EtherCAT/CANopen unit
conversion value input error
0x6320-80-0073 Switch reset
(Note) X: No alarm code output function

Table of Contents