Controls, Connectors, and
lndicators-2230
Operators
A SEC/DIV
Switch-Selects
the calibrated A
Sweep rates from 0.5 s to 0.05 µs/div
in
a 1-2-5
sequence of
22
steps for the A Sweep generator
and sets the delay time scale factor for delayed-
sweep operation.
In
STORE mode, the A SEC/DIV switch controls
the default Storage, Acquisition, Process,
and
Display modes when making acquisitions using
the A Time Base. It also selects the external
clock signal, from the EXT CLK input, for the
storage acquisition circuitry.
B SEC/DIV
Switch-Selects
the calibrated B
Sweep rates from
50
ms/div to 0.05 µs/div
in
a
1-2-5 sequence of
19
steps.
In
STORE mode, the B SEC/DIV switch controls
the default Storage, Acquisition, Process,
and
Display modes when making acquisitions using
the B Horizontal mode.
UNTRIGGERED mode performs acquisitions
without reference to the trigger circuit,
and
there
is no trigger marker
on
the screen. Triggers
are
ignored
in
STORE mode at SEC/DIV settings of
5 s per division to
0.1
s per division under the
following conditions:
ROLL
is
selected. Selecting ROLL forces the
screen to continuously update
as
on
a chart
recorder. Triggers would stop the display.
ROLL
is
operational at sweep speeds slow
Table 3-2
Default Digital Storage Modes
UN-TRIG
8
TRIGb
SLOW
RECORD
5 s to
0.1
s 5 s
to
0.1
s
50
ms
to 20
11s
or
EXT
CLK
or EXT
CLK
SAMPLEc
OFF
OFF
OFF
AVERAGEc
OFF
OFF
ACCPEAKc
OFF OFF
PEAKDETc
ON ON
ON
SMOOTHd
ON
ONe
ON
VECTORS
ON ON ON
8
See
the "UNTRIGGERED" discussion.
bSee the "TRIGGERED" discussion.
crhese Storage modes are mutually exclusive.
dWorks with ACCPEAK and PEAKDET only.
~Functions with PEAKDET only.
3-6
¢'~:-@
: A
BOTH
B i
24
...•
,HORIZONTAL
M::i---@DE··,
i II I I i
sec
5
'.>~t;ir;r'ive
STOREONLY
•~,·
..
··
..
".·.sr.o.a
..
E
..
····.'
..
·.···•.·.
8
OISABLEO
'1.:<1:1·>,'
BDELAYog·o·-·-,
21
TIME
,
POSITION
-~
--
4998-06
Figure 3-3. Horizontal controls.
FAST
RECORD
REPETITIVE
10
µS
to 5
µS
2
µS
to 0.05
µS
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
DOTS only

Table of Contents