Appendix A: Specifications
A–14
THS710A, THS720A, THS730A & THS720P User Manual
DMM Specifications (Cont.)
/Resistance
R
ang
es
an
d
Res
olution Range Resolution
400.0 0.1
4.000 k 1
40.00 k 10
400.0 k 100
4.000 M 1 k
40.00 M 10 k
n
A
ccu
r
acy
Range Maximum Error
All ranges except 40 M
±(0.5% of reading + 2 counts)
40 M
±(2% of reading + 5 counts) for
60% relative humidity
B
ia
s
Voltag
e
f
o
r
F
ull
e Res s e
Range Full Scale Bias Voltage
Scal
e
Res
i
s
tanc
e
e s reme
400.0
350 mV
M
e
a
s
u
reme
nt, typical
4.000 k
200 mV
40.00 k
350 mV
400.0 k
350 mV
4.000 M
400 mV
40.00 M
1.10 V
O
p
e
n
C
i
r
cuit Voltag
e
, Range Open Circuit Voltage
typical
400.0
4.8 V
All other ranges 1.2 V