EasyManua.ls Logo

Tektronix TG8000

Tektronix TG8000
498 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HDVG7 HDTV Digital Video Generator module
MOVING PICTURE
. Scrolls the active picture area of the output test signal. Select
this menu item, and then press the ENTER button to access the MOVING
PICTURE submenu. (See page 3-235.)
OVERLAY. Selects an item (logo, text, or circle) that is overlaid on the output test
signal and sets the blinking mode for the overlay. Select this menu item, and then
press the EN
TER button to access the OVERLAY submenu. (See page 3-293.)
AUDIO (EMBEDDED). Sets the parameters for embedded audio on the output test
signals. Use the left () or right () arrow button to select Group 1, Group 2,
Group 3,orGroup 4. Select any of the items, a nd then press the ENTER button
to access the AUDIO GROUP submenu. (See page 3-241.)
TIMING. Sets the timing offset of the serial digital video outputs relative to the
internal reference signal (frame reset signal). Select this menu item, and then
press the ENTER button to access the TIMING submenu. (See page 3-244.)
TIMECODE. Sets the timecode parameters for the module outputs when a
GPS7 m
odule is installed. To support this capability, the module hardware must
be version 2.0 or above. Select this menu item, and then press the ENTER button
to access the TIMECODE submenu. (See page 3-245.)
VIDEO. Enables or disables the Y, Pb, or Pr component of the output serial digital
video signals and the output mode for audio/video timing m easurement. Select
thi
s menu item, and then press the ENTER button to access the VIDEO submenu.
(See page 3-246.)
BLACK (OPTION). This menu is only available with Option BK, and sets the
parameters of the serial digital black signals output from the BLACK 1 and
BLACK 2 connectors. Select this menu item, and then press the ENTER button
t
oaccesstheBLACKsubmenu. (Seepage3-248.)
HD RATE. This menu item is only available with Option BK, and sets the HD
trilevel sync rate for the signal outputs. Use the left ()orright() arrow
buttontoselectNon-integer (59.94, 29.97, 23.98) or Integer (60, 50, 30, 25, 24).
Press the ENTER buttontoconrm the selection. The HD trilevel sync rate
selection affects which signal formats can be output from the module (integer or
non-integer).
3–234 TG8000 Multiformat Test Signal Generator User Manual

Table of Contents

Other manuals for Tektronix TG8000

Related product manuals