The following methods are available for updating the Adapter2 device’s firmware remotely:
Updating in case that you use a TELLMon receiver:
- Directly from the TELLMon receiver, by loading the firmware file in the receiver.
- Using the programming software, via the TELLMon protocol.
- Using the programming software, via the TEX protocol.
- Using the programming software, over the cloud.
Updating in case that you use an MVP.next server:
- Using the programming software, via the TELLMon protocol.
- Using the programming software, via the TEX protocol.
- Using the programming software, over the cloud.
Updating in case that you use a TEX-MVP or a TEX BASE/PRO server:
- Using the programming software, via the TEX protocol.
- Using the programming software, over the cloud.
Updating in case that you use a SIA DC-09 compatible IP receiver:
- Using the programming software, over the cloud.
8 Restoring the factory default settings
You can restore the factory default settings using the programming software.
Restoring the factory default settings will delete all settings and the event logs in the device, and
will restore the factory default values, including the device password! Create a system backup if
needed, before performing the factory reset.
To restore the factory default settings, click on the Restore factory default settings button
in the Connection typemenu. The reset process may take more than 1 minute, and it will restart
the device. Wait until the device restarts and the status LED on the device shows activity again.
The option of restoring the factory default settings is also available when you connect to the device
without entering the device password.
Restoring the factory default settings will be refused by the device if the Locked” option has been
selected in the “Locking the device” section, in the Advanced settings” menu. In this case, the
software will show an error message about that, after the information message shown right after
the confirmation. If you have forgotten the superadmin password, and the device has been locked
with the mentioned option, only the manufacturer can restore the factory default settings in the
service center.