13.8 Configuration
13.8.1 Data
Class Subclass Name Type Min Max Default Unit Description
Configuration Data
Manufacturer
Date
U2 0 65535 01/01/80
ManufacturerDate() value in the following
format:Day + Month*32 + (Year–1980) * 512
Configuration Data Serial Number H2 0x0000 0xFFFF 0x0001 SerialNumber() value
Configuration Data
Manufacturer
Name
S20+1
Texas
Instruments
ASCII ManufacturerName() value
Configuration Data Device Name S20+1
BQ28Z610-
R2
ASCII DeviceName() value
Configuration Data
Device
Chemistry
S4+1 LION ASCII DeviceChemistry() value
13.9 Lifetimes
13.9.1 Voltage
Class Subclass Name Type Min Max Default Unit Description
Lifetimes Voltage Max Voltage Cell 0 I2 0 32767 0 mV Maximum reported cell voltage 0
Lifetimes Voltage Max Voltage Cell 1 I2 0 32767 0 mV Maximum reported cell voltage 1
13.9.2 Current
Class Subclass Name Type Min Max Default Unit Description
Lifetimes Current Max Chg Current I2 0 32768 0 200 mA Maximum reported Current() in charge direction
Lifetimes Current Max Dsg Current I2 –32768 0 0 200 mA Maximum reported Current() in discharge direction
13.9.3 Temperature
Class Subclass Name Type Min Max Default Unit Description
Lifetimes Temperature Max Temp Cell I1 –128 127 –128 °C Maximum reported cell temperature
Lifetimes Temperature Min Temp Cell I1 –128 127 127 °C Minimum reported cell temperature
13.10 Protections
13.10.1 CUV—Cell Undervoltage
Class Subclass Name Type Min Max Default Unit Description
Protections CUV Threshold I2 0 32767 2500 mV Cell undervoltage trip threshold
Protections CUV Delay U1 0 255 2 s Cell undervoltage trip delay
Protections CUV Recovery I2 0 32767 3000 mV Cell undervoltage recovery threshold
13.10.2 COV—Cell Overvoltage
Class Subclass Name Type Min Max Default Unit Description
Protections COV
Threshold Low
Temp
I2 0 32767 4300 mV
Cell overvoltage low temperature
range trip threshold
Protections COV
Threshold
Standard Temp
I2 0 32767 4300 mV
Cell overvoltage standard temperature
range trip threshold
Protections COV
Threshold High
Temp
I2 0 32767 4300 mV
Cell overvoltage high temperature
range trip threshold
Protections COV
Threshold Rec
Temp
I2 0 32767 4300 mV
Cell overvoltage recommended
temperature range trip threshold
Protections COV Delay U1 0 255 2 s Cell overvoltage trip delay
Protections COV
Recovery Low
Temp
I2 0 32767 3900 mV
Cell overvoltage low temperature
range recovery threshold
Protections COV
Recovery
Standard Temp
I2 0 32767 3900 mV
Cell overvoltage standard temperature
recovery range threshold