12.1.9 0x10/11 RemainingCapacity()
This read-word function returns the predicted remaining battery capacity.
SBS Cmd Name
Access
Proto-
col
Type Min Max Unit
SE US FA
0x10/11 RemainingCapacity() R Word U2 0 65535 mAh
12.1.10 0x12/13 FullChargeCapacity()
This read-word function returns the predicted battery capacity when fully charged.
SBS Cmd Name
Access
Proto-
col
Type Min Max Unit
SE US FA
0x12/13 FullChargeCapacity() R Word U2 0 65535 mAh
12.1.11 0x14/15 AverageCurrent()
SBS Cmd Name
Access
Proto-
col
Type Min Max Unit
SE US FA
0x14/15 AverageCurrent() R Word I2 –32767 32768 mA
12.1.12 0x16/17 AverageTimeToEmpty()
This read-word function returns the predicted remaining battery capacity based on AverageCurrent().
SBS Cmd Name
Access
Proto-
col
Type Min Max Unit Note
SE US FA
0x16/17 AverageTimeToEmpty() R Word U2 0 65535 min
65535 = Battery is not being
discharged.
12.1.13 0x18/19 AverageTimeToFull()
This read-word function returns the predicted time to full charge based on AverageCurrent().
SBS Cmd Name
Access
Proto-
col
Type Min Max Unit Note
SE US FA
0x18/19 AverageTimeToFull() R Word U2 0 65535 min
65535 = Battery is not being
discharged.
12.1.14 0x1A/1B StandbyCurrent()
SBS Cmd Name
Access
Proto-
col
Type Min Max Unit
SE US FA
0x1A/1B StandbyCurrent() R Word I2 –32767 32768 mA
12.1.15 0x1C/1D StandbyTimeToEmpty()
This read-word function returns the predicted remaining battery capacity based on the minimum load rate of
discharge.
SBS Cmd Name
Access
Proto-
col
Type Min Max Unit Note
SE US FA
0x1C/1D StandbyTimeToEmpty() R Word U2 0 65535 min
65535 = Battery is not being
discharged.
12.1.16 0x1E/1F MaxLoadCurrent()
This read-word function returns the maximum load conditions based on adaptive measurements, using the
values in the initial Max Load Current register and the measured Max Load Current.
www.ti.com I2C Commands
SLUUCO0 – APRIL 2022
Submit Document Feedback
BQ28Z610-R2 69
Copyright © 2022 Texas Instruments Incorporated