1 = Active
0 = Inactive
CB (Bit 28): Cell Balancing
1 = Active
0 = Inactive
SLPCC (Bit 27): CC measurement in SLEEP mode
1 = Active
0 = Inactive
SLPAD (Bit 26): ADC measurement in SLEEP mode
1 = Active
0 = Inactive
SMBLCAL (Bit 25): Auto-offset calibration when bus low is detected.
1 = Active
0 = Inactive
INIT (Bit 24): Initialization after full reset
1 = Active
0 = Inactive
SLEEPM (Bit 23): SLEEP mode
1 = Active
0 = Inactive
XL (Bit 22): 400-kHz mode
1 = Active
0 = Inactive
CAL_OFFSET (Bit 21): Calibration Output (raw CC Offset data)
1 = Active when MAC OutputShortedCCADCCal() is sent and the raw shorted CC data for calibration is available.
0 = When the raw shorted CC data for calibration is not available.
CAL (Bit 20): Calibration Output (raw ADC and CC data)
1 = Active when either the MAC OutputCCADCCal() or OutputShortedCCADCCal() is sent and the raw CC and ADC data for
calibration is available.
0 = When the raw CC and ADC data for calibration is not available.
AUTHCALM (Bit 19): Auto CC Offset Calibration by MAC AutoCCOffset()
1 = The gauge receives the MAC AutoCCOffset() and starts the auto CC Offset calibration.
0 = Clear when the calibration is completed.
AUTH (Bit 18): Authentication in progress
1 = Active
0 = Inactive
RSVD (Bit 17): Reserved
SDM (Bit 16): SHUTDOWN triggered through a command
1 = Active
0 = Inactive
SLEEP (Bit 15): SLEEP mode conditions met
1 = Active
0 = Inactive
SEC1, SEC0 (Bits 14, 13): SECURITY mode
www.ti.com I2C Commands
SLUUCO0 – APRIL 2022
Submit Document Feedback
BQ28Z610-R2 83