To do this, complete the following steps:
1. Disconnect your UltraSync ONE from the device that provided the timecode.
Your UltraSync ONE will now free run, using the timecode that was received
from the external device.
2. Set your UltraSync ONE to Master TX mode.
3. Connect your UltraSync ONE to a different external device.
You can connect it via the:
l LTC port. Use the blue DIN 1.0/2.3 to BNC cable that is supplied with
your UltraSync ONE.
l SYNC port. Use the red DIN 1.0/2.3 to BNC cable that is supplied with
your UltraSync ONE.
4. If you connected via the SYNC port, use the Set Sync O/P Mode option to set
the UltraSync ONE to output LTC. Ignore this step if you connected via the
LTC port.
5. Configure the device that is connected to your UltraSync ONE so that it can
receive timecode. See the device manufacturer's instructions for more
details.