UltraSync ONE Slave not Connecting to Master
If your UltraSync ONE is not receiving timecode from a master device, it could be
due to:
l The master device being switched off. Make sure the master device is on and
has sufficient battery power.
l UltraSync ONE is set to Master TX mode. The UltraSync ONE can only connect
with a master device if the UltraSync ONE is running in RF Slave mode. For
more information, see Networks and Modes on page 23).
l The master is out of range. The UltraSync ONE will use its own timecode
settings until a master is back in range. An UltraSync ONE that is using its own
timecode settings is described as 'free running'.
l The UltraSync ONE is not set to use the same RF Channel as the master.
UltraSync ONE slave - master communications can only take place between
devices that are in the same RF network. For more information, see Set the
RF Channel on page 68.
l The UltraSync ONE and/or the master are not set to the correct
country/area. You need to set the UltraSync ONE and master to the
country/area in which they are being used (see Set the RF Country/Area on
page 64).
UltraSync ONE Slave is Connecting to the Wrong Master
If your UltraSync ONE is running in slave mode and connects to the wrong master
device, it is likely that there are multiple masters in the same RF network. An RF
network should only have one master device (one master using the specific RF
channel for the network. For details, see Quick Set Up: UltraSync ONE as Master TX
on page 1).
UltraSync ONE not Responding to Select button
In the unlikely event that your UltraSync ONE does not display the menu when you
press the Select button, try a Reset (see page 106).
UltraSync ONE User Guide 103