EasyManuals Logo

Topcon GR-5 User Manual

Topcon GR-5
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #97 background imageLoading...
Page #97 background image
Configuring the Receiver Using TRU
P/N 7010-1004
3-25
Maximum distance: if the point has been previously
occupied and the receiver position falls within proper
tolerance, it will select a point from positions stored in
memory.
Enable averaging mode: select to enable averaging
autonomous positions for a occupation point with the interval
set in the Position averaging interval field in seconds.
Figure 3-22. Base Configuration
Click View the point list to open a list of previous occupations
saved in the receiver memory. This Auto Seed, Point List
contains information about all occupations which stored in the
receiver memory: names, date and time, coordinates of phase
center and/or antenna reference point, whether the point was auto
determined and protected from deleting. For details on
configuring the Auto Seed functionality, refer to the TRU
Reference Manual.
NOTE
To specify your base station coordinates without
using Auto Seed, go to Terminal and enter the
coordinates using the corresponding GRIL
command.

Table of Contents

Other manuals for Topcon GR-5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Topcon GR-5 and is the answer not in the manual?

Topcon GR-5 Specifications

General IconGeneral
BrandTopcon
ModelGR-5
CategoryReceiver
LanguageEnglish

Related product manuals