Configuring the Receiver Using TRU
P/N 7010-1004
3-25
Maximum distance: if the point has been previously
occupied and the receiver position falls within proper
tolerance, it will select a point from positions stored in
memory.
Enable averaging mode: select to enable averaging
autonomous positions for a occupation point with the interval
set in the Position averaging interval field in seconds.
Figure 3-22. Base Configuration
Click View the point list to open a list of previous occupations
saved in the receiver memory. This Auto Seed, Point List
contains information about all occupations which stored in the
receiver memory: names, date and time, coordinates of phase
center and/or antenna reference point, whether the point was auto
determined and protected from deleting. For details on
configuring the Auto Seed functionality, refer to the TRU
Reference Manual.
NOTE
To specify your base station coordinates without
using Auto Seed, go to Terminal and enter the
coordinates using the corresponding GRIL
command.