Toro 31900A - Servicing the Air Cleaner

Toro 31900A
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Servicing the Air Cleaner
Service Interval : Before each use or daily —Check
the air-cleaner restriction indicator
and replace the lter elements if
necessary .
Every 250 hours —Change the air-cleaner
element.
Check the air-cleaner body for damage, which could
cause an air leak. Replace the body if it is damaged.
Check the intake system for leaks, damage, or loose
hose clamps
Service the air-cleaner element only when the
restriction indicator ( Figure 55 ) requires it. Changing
the air cleaner element before it is necessary
increases the chance of dirt entering the engine when
you remove the element.
g009709
Figure 55
1. Air-cleaner restriction indicator
Important: Ensure that the cover is seated
correctly and seals with the air-cleaner body and
that the latches are closed properly .
1. Replace the air lter element ( Figure 56 ).
g253706
Figure 56
Important: Do not clean a used element;
cleaning it can damage the lter media.
2. Reset the restriction indicator ( Figure 55 ) if it
shows red.