- 26 -
< 6 > A U T O C A L I B
O F F
(17) The current setting is displayed.
[FEED] or [RESTART]
(18) Change the setting using the [FEED] or
[RESTART] key.
< 6 > A U T O C A L I B
O N T R A N S .
(19) Automatic calibration for the Transmissive
sensor
[FEED] or [RESTART]
(20) Change the setting using the [FEED] or
[RESTART] key.
< 6 > A U T O C A L I B
O N R E F L E C T
(21) Automatic calibration for the Reflective sensor
[PAUSE]
(22) Press the [PAUSE] key to save the setting.
< 6 > A U T O C A L I B
(23) The automatic calibration menu is displayed.
Automatic calibration setting (AUTO CALIB)
OFF Disabled
ON TRANS. The transmissive sensor is enabled.
ON REFLECT The reflective sensor is enabled.
Explanation of operation
(1) When AUTO CALIB is enabled, an automatic calibration starts at an open/close of the print head
after the power is turned on.
(2) When AUTO CALIB is enabled, the media length, effective print length, sensor type, and whether
to use ribbon or not specified by commands are ignored.
(3) When “ON REFLECT” is selected, the lowest voltage detected by the black mark sensor is
considered as a black mark level. And, the sum of this voltage and the manual threshold
voltage will be adopted as a threshold.
(4) When “ON TRANS” is selected, the highest voltage detected by the feed gap sensor is
considered as a gap level. After subtracting the manual threshold voltage from this voltage, the
result will be adopted as a threshold.