6.2.4 Self-test Printout Contents
(1) Maintenance counter
Item Contents Range
TOTAL FEED Total label distance covered
(cannot be cleared)
0.0 to 3200.0 km
FEED Label distance covered 0.0 to 3200.0 km
PRINT Print distance 0.0 to 200.0 km
CUT Cut count 0 to 1000000
HEAD U/D Head up/down count 0 to 2000000
RIBBON Ribbon motor drive time 0 to 2000 hours
SOLENOID Head-up solenoid drive time 0 to 1000 hours
232C ERR RS-232C hardware error count 0 to 255
SYSTEM ERR System error count 0 to 15
POWER FAIL Momentary power interruption count 0 to 15
RFID WT OK
TAGS
Number of successful RFID write 0 to 9999999
RFID VOID
PRINT TAGS
Number of failure in RFID write 0 to 9999999
Maintenance Counter Count Conditions
Total label distance covered
Label distance covered
Counts when the paper feed motor is driven to feed a
paper or print. (Counts also during a reverse feed
operation.)
When the power is off, the label distance of 50.0 cm or less
may be rounded down and backed up.
Print distance Counts while printing. (Counting is not performed during
reverse feed operation.)
B-SX4:
When the power is off, the print distance of 8.2 m or less
is rounded down and backed up.
B-SX5:
When the power is off, the print distance of 5.5 m or less
is rounded down and backed up.
Cut count Every cut operation is counted.
When the power is off, a cut count of 31 or less is rounded
down and backed up.
Head up/down count Counts head up/down operations using the ribbon saving
solenoid. (Combination of up and down operations is
counted as one.)
When the power is off, an up/down count of 31 or less is
rounded down and backed up.
Ribbon motor drive time Counts when the ribbon motor is driven to feed a paper or
print. (Counts also during a reverse feed operation.)
For B-SX4:
When the power is off, a drive time of 32 seconds or less is
rounded down and backed up.
For B-SX5:
When the power is off, a drive time of 27 seconds or less is
rounded down and backed up.