3.3 Check of the RAID configuration 3 Tests and Diagnostics
The RAID is not configured by two drives in the following display, because there are two
LDs (LD0 and LD1).
TOSHIBA RAID / RAID Information Display Rev xx.xx.xxxx
Copyright(c) 2005 TOSHIBA CORPORATION. All Rights Reserved.
Level Status Capacity
LD0 RAID-0 OPTIMAL xxGB
Write cache : Enable
Degrade Bootup : Yes
MBR Protection : Disable
S.M.A.R.T : Enable
LD1 RAID-0 OPTIMAL xxGB
Write cache : Enable
Degrade Bootup : Yes
MBR Protection : Disable
S.M.A.R.T : Enable
Port Assign Status Size Model Rev
0 LD0-0 ONLINE xxGB FUJITSU-------------- xxxxxxx
1 LD0-0 ONLINE xxGB FUJITSU-------------- xxxxxxx
< RAID: RAID-0 >
3.3.2.3 RAID-0 (2)
When there is one LD and “RAID-0 Critical” is displayed in the shown below, it is
judged that the RAID is configured by two drives.
Level Status Capacity
LD0 RAID-0 CRITICAL xxGB
Stripe Size : 64KB
Write cache : Enable
MBR Protection : Disable
S.M.A.R.T : Enable
Port Assign Status Size Model Rev
0 LD0-0 ONLINE xxGB FUJITSU-------------- xxxxxxx
1 NODRIVE
< RAID: not OPTIMAL >