Appendix J   Maintenance of TOSHIBA RAID  Appendices 
QOSMIO G30  Maintenance Manual (960-546)  [CONFIDENTIAL]  J-7 
(2) Check if it is caused by an operation miss or is a failure. 
To check if the cause of failure of Port1 is an operation miss or not, analyze the Drive 
Log of Port0. 
1.  In [REDUNDANT] of Port-0, find a log of “Fail this drive” message by [PgUp] 
and [PgDn] key. 
2.  If no message of “Fail this drive” message, it is judged that the second HDD is 
removed without the operation of removal by TOSHIBA RAID console and 
installed again.  
(3) How to change the status to OFF LINE 
Release the status of “Fail”, using the menu of [Force OFFLINE]. This HDD is not 
necessary to be repaired.