Voice Mail Configuration
Telephone Systems
3-8 Strata CIX Voice Mail Programming 01/07
Table 3-2 Telephone Systems Tab Screen Fields
FIELD DESCRIPTION
Integration Group Name Alphanumeric field. Underscores are allowed. If you type in more than one word, the
Stratagy ES adds an underscore between words when it updates.
Note The Integration Group Name, once entered and saved in this screen, is
automatically added to the Telephone System Integration Name drop-down
menu in the Answer Methods screen.
Switch Type Designates the telephone system switch type.
Important! If you accidently enter only spaces in this field, voice mail does not
reject it. Instead, voice mail accepts the invalid pure space name and
uses it as a switch type.
Defaults to Strata CIX. Possible values are: Strata CIX, <Create/save Switch Type>.
Integration Type Defaults to CTX Proprietary.
Important! For Strata CIX, do not change the default on this field.
Possible values are: DTMF, SMDI and CTX Proprietary. If you choose SMDI, the
Serial Port and Max. Ext. Length fields to the right on the screen must be filled in.
Serial Port — Defaults to blank. Possible values are: COM1~COM2.
Max. Ext. Length — Maximum number of digits the connecting switch expects to
receive, specifically for message notification. Standard is 10. Some switches are
limited to seven digits.
Possible values: 1~10
Note The Stratagy ES will send the number of digits specified here. If the actual
mailbox extension number has a smaller quantity of digits than this value,
voice mail will insert the appropriate quantity of digits.
Example: Max. Ext. Length = 10
Mailbox/Ext. Number = 3752
Voice mail sends 0000003752.
Line Type This field designates the line type as IP Proprietary.
Defaults to IP Proprietary (cannot be changed).
Integration Pattern If your telephone system supports integration, this selection controls the definition of
its integration. Perform this step only to refine, verify, or modify the integration of the
Stratagy ES system with your telephone system.
Notes
© This field is not applicable to the Strata CIX.
© Integration patterns support only Analog Integration.