4 Replacement Procedures 4.15 Fingerprint sensor board
Installing the Fingerprint sensor board
To install the fingerprint sensor board, follow the steps below and refer to Figure 4-25 and 4-
26.
NOTE: When installing a new fingerprint sensor board, make sure that the insulators
and gasket are placed as shown in the following figure.
1. Connect the fingerprint sensor cable to the connector on the fingerprint sensor
board.
2. Stick a new double-sided tape in place and install the fingerprint sensor board
while inserting it into the guides.
CAUTION: Do not reuse the removed double-sided tape.
3. Install the fingerprint sensor board hold plate while sliding it into the guides.
4. Arrange the fingerprint sensor cable and stick the glass tape in place.
4-44 [CONFIDENTIAL] TECRA A9/TECRA S5/TECRA P5/Satellite Pro S200 Maintenance Manual (960-633)

Table of Contents

Other manuals for Toshiba TECRA A9 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TECRA A9 Series and is the answer not in the manual?

Toshiba TECRA A9 Series Specifications

General IconGeneral
ProcessorIntel Core 2 Duo
Display15.4-inch
Display Resolution1280 x 800 pixels
RAMUp to 4 GB
Operating SystemWindows Vista
Optical DriveDVD-RW
Wireless802.11a/g/n
PortsUSB 2.0, VGA, Ethernet, Headphone

Related product manuals