E6582233
F-70
6
Title Function Ad
j
ustment ran
g
e Default settin
g

Communication time-out detection
condition
0: Valid at any time
1: Communication selection of
fmod or cmod
2: 1
during operation
1

Selection of communication
protocol
0: Toshiba inverter protocol
1: ModbusRTU protocol
0
 Block write data 1
0: No selection
1: Command information
2: -
3: Frequency setting
4: Output data on the terminal
board
5: Analog output for
communication
0
 Block write data 2 0

Block read data 1
0: No selection
1: Status information
2: Output frequency
3: Output current
4: Output voltage
5: Alarm information
6: PID feedback value
7: Input terminal board monitor
8: Output terminal board monitor
9: VI terminal board monitor
0

Block read data 2 0
