331
16.2.2 SFlow Sampler
Figure 16-4 sFlow Sampler
Configuration Procedure:
Configure one or more ports to be a sampler and configure relevant parameters under the
Sampler Config. One port can only be bound to one collector.
Entry Description:
Select Configure the desired port to be the sFlow sampler.
Port: Displays the port of the switch here.
Collector ID:
Select the sFlow collector for the sFlow sampler. The sampler will
send sFlow data
grams to corresponding collector via the sFlow
agent. When the C
ollector ID is 0, it means no collector is
selected.
Ingress Rate:
Specify the ingress sampling frequency of the sFlow sampler.
When a sample is taken, the value indicates how many packets to
skip before the next sample is taken.
Egress Rate:
Specify the egress sampling frequency of the sFlow sampler.
When a sample is taken, the value indicates how many packets to
skip before the next sample is taken.
Max Header: Specify the maximum number o
f bytes that should be copied from
a sampled packet.
LAG: Displays the LAG number which the port belongs to.