6.Refrigerant doesn’t circulate in the Air conditioning system
Pressure Low pressure : Negative pressure(Low)
High pressure: 6 kg/(Low)
Situation Deficient air conditioning
(Not cool)
Cool occasionally
Cause Clogged in the Expansion valve hole
(Clogged by foreign matter or freezing,
dust)
Estimate Clogged in the expansion valve
Remedy Remove the wet:Replenish the refrigerant
Remove dust:Disassemble the expansion
valve and clean with air lower and replace
Replace the receive dryer:Leakage in the
expansion valve replace
7.Defect of the compressor pressure
Pressure Low pressure : 4~6 kg/(High)
High pressure: 7~10 kg/(Low)
Situation Deficient air conditioning
(Not cool)
Cause Compressor inside leakage
Estimate Defect pressure of the compressor
(Valve leakage or damaged)
Remedy Repair or replace