12-16
4.mixed Air in the air conditioning system
Pressure Low pressure : 2.5 kg/(High)
High pressure: 23 kg/(High)
Situation Deficient of cooling condition
(Not cool)
Not cool when touch the low pipe
Cause Air was mixed in the air conditioning
system
Estimate Defect of the vacuum work in the air
conditioning system
Remedy Remove the vacuum and replenish the
refrigerant
Contaminated oil in the condenser:
Clean and replace
Replace the receive dryer
5.mixed H2O in the air conditioning System
Pressure Low pressure : Low~1.5 kg/
(Low or vibrate seriously)
High pressure: 7~15 kg/
(Low or vibrate seriously)
Situation Air conditioning is cool and is not
periodically
Manifold gauge pressure is
occasionally down or normal
Cause The expansion valve is freezing
occasionally Mixed with H2O in the air
conditioning system
Estimate Receive dryer is over-saturation
H
2O was freezing in the expansion
valve
Remedy Replenish the refrigerant
Replace the receive dryer