105
direction detected by the IMU exceeds 10°, the software will pop-up
prompts.
【Floor (0 °, 0 °)】
The default method is horizontal installation, and the horizontally
mounted robotic arm does not need a tilt angle and a rotation angle.
【Ceiling (180 °, 0 °)】
For ceiling-mount, users simply need to set the mounting method as
ceiling, and it is not necessary to set the angle of rotation.
【WallUp (90 °, 180 °)】
Indicates that the robotic arm is wall-mounted and the end of the
robotic arm is facing up.
WallDown (90 °, 0 °)】
Indicates that the robotic arm is wall-mounted and the end of the
robotic arm is facing down.
Customized
Mount at other angles. For mounting at a certain angle. It is necessary
to set the tilt angle and the rotation angle according to the actual
situation.
How to determine the tilt angle and rotation angle?