the orientation of the end-effector must be
archived as a file.
3. Make sure that the tool is safely constructed such
that it cannot create a hazardous situation by
dropping a part unexpectedly.
4. Pay attention to the operation specifications of
sharp end-effector tools.
5. If the installed end-effector exceeds the robotic
arm mounting surface at the zero position of the
robotic arm, a safety assessment is required for the
zero return operation.
1.3. Power Supply for the Robotic Arm
1.3.1. Preparation before Power On
Ensure the power cable and the communication wire are properly
connected between the Control Box and the robotic arm.
Ensure the network cable or RS-485 cable is properly connected.
Ensure the power cable for the Control Box is properly connected.
Ensure the xArm will not hit any personnel or equipment within
the working range.