multiMATIC 700/2
Notes
10/2015 104 Training 0020228700_00
7.2 Checklist
Settings matrix: System diagram and configuration for the VR 70, VR 71
System diagram
*1
No
VR 70
Configuration
for the VR 70
VR 71
1
3
5
6
12
2 heating
circuits
allSTOR
2 mixed
circuits
Solar hot
water gen-
eration
Solar
heating
support
3 mixed circuits
1 direct
heating
circuit
1 direct and
1 mixed
heating circuit
1 direct and
1 mixed
heating
circuit
2 mixed
heating
circuits
1 direct
heating
circuit
1 mixed
heating
circuit
3 mixed heat-
ing circuits
1
System with boiler: DHW regula-
tion by boiler (except in solar
systems)
2
System with boiler: DHW regula-
tion by VRC 700
6
3 kW hybrid system (alternative
mode of operation): DHW only
by boiler
7
3 kW hybrid system (parallel
operation with 2 circuits/zones):
DHW only by boiler
8
Mono-energy HP system, AH
requires HP (DHW by HP and
AH)
Simple hybrid system, AH does
not require HP (DHW by boiler
only)
9
Simple hybrid system, AH does
not require HP, DHW by boiler
only
10
HP system with heat exchanger,
AH requires heat exchanger
pump, mono-energy (DHW only
by HP)
11
Mono-energy HP system with
heat exchanger, AH requires HP
(DHW by HP and AH)
12
Complete hybrid system, AH
does not require HP, DHW by
HP and boiler
13
Complete hybrid system with
heat exchanger, AH does not
require HP, DHW by HP and
boiler
If a combination of "System diagram" and module configuration is selected that is not
permitted, the fault message "System diagram selection incorrect" or "VR 70 con-
figuration incorrect" is displayed on the controller.