multiMATIC 700/2
Notes
10/2015 49 Training 0020228700_00
4.4.2.1 Information
The "Information" menu item allows users
and the competent person to read the sta-
tus of all the important values in the sys-
tem quickly.
If help is required, the user will find the
name and telephone number of the spe-
cialist company that can help with queries
relating to the controller and its serial
number.
Prompt
Select
Comment
Fault status
No fault, Fault list
If "Fault list" is displayed, the cause of the warning can be
found using the "Display" button.
Water pressure
Display in bars
If the heat generator has been fitted with a water pressure
sensor, the current heating water pressure in the heat gen-
erator is displayed.
System status
Standby, Heat.
mode, Cooling,
DHW
Displays the current status of the system
Collector temp.
Display in °C
Only with the VR 70 = 6, 12
(The calculated solar yield of the VPM S, VPM D, VMS
and auroSTEP plus is also transferred to the VRC 700)
Solar yield
Display in kWh
Reset solar yield
Yes, No
Environmental yield
Display in kWh
Only in conjunction with geoTHERM 3 kW, aroTHERM
and flexoTHERM
Reset environmen-
tal yield
Yes, No
Current room air
hum.
Display in %
Display only for wall-mounted controllers
triVAI
Only in conjunction with geoTHERM 3 kW, aroTHERM
and flexoTHERM, if Hybrid manager = triVAI
ZONE 1 / ZONE 2 / ZONE 3
*1
Day temp. heating
5.030.0 °C
Displays the current target value for the room temperature
during heating
System status
Information
System status
Contact details
Serial number
Environmental yield
Solar yield
Heat recovery
Consumption
Fuel consumption
*2
Electrical consumption
*3
= With geoTHERM 3kW, aroTHERM, flexoTHERM
= With VR 70 = 6, 12
= With recoVAIR …/4
= With ecoTEC exclusive …/5, flexoTHERM
*1
: Two zones with VR 70 = 1, 5 /three zones with VR 71
*3
: Also with ecoTEC exclusive, VR 71
*2
: Not with flexoTHERM, VR 71

Table of Contents