5.2 Start-up
*
Confirming with "OK" opens the "Installer level > System configuration" menu. The
installation assistant has finished and the rest of the installation-specific parameters
must now be set here.
The installation assistant will launch automatically when the controller is started for the
first time following installation of electrical wiring or following replacement.
The range of setting options available in the "System configuration" menu depends on
the system components detected, the configuration set for the VR 70 and the VR 71
and the system diagram that has been set.
5.2.1 Settings in the Installation assistant
Prompt
Select
Comment
Language
DE, GB, FR, IT, DK, NL, ES,
TR, HU, RU, UA, EE, LV, LT,
SE, NO, PL, CZ, HR, SK, RO,
SI
System diagram
1 13
System diagrams 3, 4, and 5 are currently
not supported.
VR 70 1 config.
1 12
VR 70 configurations 2, 4, 7, 8, 9, 10 and 11
are currently not supported.
System configuration
Since only setting "3" is currently supported for the VR 71 mixer module, it is
not possible to view or adjust the module's configuration.
Installation assistant
System diagram
Language
System configuration *
VR 70 1 Adr. 1 config.