multiMATIC 700/2
Notes
10/2015 54 Training 0020228700_00
The set temperature applies to:
Automatic mode: Within the time periods programmed for a week.
Comfort mode
4.4.2.4 Time programmes
Up to three time windows may be set per day
or block. The minimum interval is 10
minutes. The times set at the factory for each
of the time programmes are:
ZONE, DHW circuit, Circulation:
Mo Fr 06:00 22:00
Sat. 7:30 23:30 hours
Sun 7:30 22:00 hours
Ventilation, Noise reduction operation:
Mo Su 00:00 00:00
High tariff:
Mo Su 11:00 13:00
Time programmes
The controller indicates any conflicts that occur during programming by showing "!!-!!"
in the time period. Example: The heating times for ZONE 1 are different on weekdays
and at weekends.
When block programming for Monday to Sunday is called up, "!! - !!" appears in order
to indicate that any time periods which have already been programmed will be deleted.
Domestic hot water
High tariff
Time programmes
ZONE 1 / 2 / 3
*1
Domestic hot water
ZONE 1 / 2 / 3: Cooling
*1
Noise reduction operation
Ventilation
Circulation
= Displayed only in conjunction with geoTHERM 3 kW, aroTHERM, flexoTHERM
= Only in conjunction with recoVAIR .../4
*1
: Two zones with VR 70 = 1, 5 / three zones with VR 71