multiMATIC 700/2
Notes
10/2015 62 Training 0020228700_00
4.5.7.1 System
Prompt/setting
Select
Comment
Fault status
No fault, Fault list
If "Fault list" is displayed, the warning can be
found using the "Display" button.
Water pressure
Display in bars
Displays the current heating water pressure.
System status
Standby, Heat. mode,
Cooling, DHW
Shows the current operating mode
Frost protect. delay
0 12 h
Delays switching on heating mode; relevant
in Automatic mode with "Eco" or "Set-back"
energy-saving options
OT constant heating
Off, -25 10 °C
Control modules
Boiler, VR 70, VR 91
Adr.1, heat pump, …
Shows the components identified at the
eBUS and their software versions
Adaptive heat. curve
No, Yes
Configure heat. circ.
All, Zone1, Zone2,
Zone3
*1
Selects which zone the "Operating mode"
button on the basic display has an effect on
Automatic cooling
No, Yes
Only in conjunction with geoTHERM 3 kW,
aroTHERM and flexoTHERM
Start OT cooling
10 30 °C
Source regeneration
No, Yes
Current room air hum.
Display in %
Display only for wall-mounted controllers
Current dew point
Display in °C
Displayed only if "Cooling possible" =
"Yes", "Room temp. mod." = "Temp.
mod." and "Zone assignment" = "VRC
700" or "VR 91" selected
Hybrid manager
triVAI, Biv. point
Only in conjunction with geoTHERM 3 kW,
aroTHERM and flexoTHERM
Bivalence point: Parallel operation with an
additional heat generator is enabled below
the temperature set here.
Alternative point: The heat pump is
switched off below the temperature set here.
Heating bivalence point
-30 20 °C
DHW bivalence point
-20 20 °C
Alternative point
Off, -20 40 °C
T. emergency mode
20 80 °C
Auxiliary heater type
Condens., Non cond.,
Electric
Energy supplier
HP off, BH off, HP&BH
off, Heating off, Cooling
off, Heat./Cool. off
Auxiliary heater for
Inactive, Heating, DHW,
DHW+heat.
Buff. cyl. offs.
0 15 K
System flow temperature
Display in °C
Only with system diagram 6 - 13
The parameters shown in bold in the first column of the table are adjustable.
*1
: Two zones with VR 70 = 1, 5 / three zones with VR 71