6.2 Fault messages
If there is a fault, a fault message appears in-
stead of the basic display after a brief waiting
period. The left button takes you back to the
basic display.
The fault message remains visible under
Menu > Information > System status >
"Fault". Press the right-hand selection button
to display the list of fault messages.
No heat generator connection
Faulty eBUS plug connection, cable defective.
Switching off all relays.
Communication fault: Heat generator
Faulty eBUS plug connection, cable defective.
Switching off all relays.
Fault in the unit; the cause of the fault can be
seen in the unit's DIA system.
Communication fault: Heat pump
Faulty eBUS plug connection, cable defective.
No additional module connection
Cable defective, plug connection not correct
Cable defective, plug connection not correct
Incorrect configuration: MA2 VWZ-AI
The controller has been incorrectly installed in a
heat generator
Room air humidity sensor fault
Room air humidity sensor defective
Communication fault: VR 70
Faulty eBUS plug connection, cable defective.
Switching off all relays.
S1, S2, S3, S4, S5, S6 sensor fault
Faulty cable, incorrect plug connection, faulty
sensor
Hot water temperature sensor S1 not connected
Faulty cable, incorrect plug connection, faulty
sensor
Incorrect configuration: VR 70