multiMATIC 700/2
Notes
10/2015 66 Training 0020228700_00
Prompt/setting
Select
Comment
Heating curve
0.1 - 4.0
System-dependent assignment of the outside
temperature to the target flow temperature.
Minimum temperature
15 90 °C
Useful when using radiators
Maximum temperature
15 90 °C
Auto Off mode
Eco, Set-back
Operating behaviour of the heating circuits
outside the programmed time periods
Room temp. mod.
None, Temp. mod.,
Thermost.
Factoring in the current room temperature in
order to achieve the target room temperature
Only if the controller is wall-mounted and
zones have been assigned for VRC 700
and/or VR 91
Cooling possible
No, Yes
Dew point monitoring
No, Yes
Displayed only if "Cooling possible" =
"Yes" selected
Min. cool. fl. tgt temp.
7 24 °C
End OT cooling
4 25 °C
Offset dew point
-10 10 K
Displayed only if "Cooling possible" =
"Yes", when "Room temp. mod." = "Temp.
mod." and "Zone assignment" = "VRC 700"
or "VR 91" selected
Status ext. heat dem.
On, Off
Displayed only with the VR 70 = 1, 5
Pump status
On, Off
Displays the status of the pump inside the unit
or the heating circuit pump
Mixer status
Stationary, Closing,
Opening
Displays the mixer movement
Only for heating circuit 2 and 3, heating
circuit 1 with VR 70 = 3, 5, 12 (mixer circuit)
or VR 71