2500 Automatic Tank Gauge
96 Installation and Operations Manual
Condensate Reservoir
The condensate reservoir is designed to collect condensate that would
otherwise accumulate in the gauge head. Its use is recommended where
an excessive amount of condensate could develop or in oil filled gauge
applications (Part #DA4O51).
Figure 24: Condensate Reservoir
Shock Absorber
The Shock Absorber reduces wear and maintenance on a 2500 ATG by
minimizing the transfer of wave energy from the float to the perforated
tape and gauge head components. It prevents the float from becoming
detached from the tape by wave action and should always be used in tanks
with turbulent conditions near inlet or outlet piping and near a mixer
(Part #DA6138).
Figure 25: Shock Absorber
Floating Roof Anchor Weight
The Floating Roof Anchor Weight rests on the floating roof pan, but is not
attached to the pan. This allows rapid movement of the floating pan without
over-stressing the 2500’s cable.
Caution The floating roof must be reinforced under the anchor
weight.
Figure 26: Floating Roof Anchor Weight
Part Numbers for Complete Gauge Heads Spare
Parts
Part #
Description
10-10712-01 Gauge Assembly, 2500 English w/Negator Cassette
10-10712-02 Gauge Assembly, 2500 Metric w/Negator Cassette
BM13661-111 Alum-English w/Check Knob