EasyManua.ls Logo

Varec 2500 - Connecting the Cable to a Float in a Floatwell

Varec 2500
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Varec, Inc. 31
Figure 10: Tape Clamp Assembly with Grounding Cable
4. Form a 'U' at the end of the perforated tape. Form it to match the 'U' piece previously
formed. Do not kink.
5. Install the gauge tape and 'U' piece to the tape connector with the tape clamps and screws
provided, making certain that the tape is not kinked or twisted.
6. Connect the grounding cable (A) to the tape connector (point B).
7. Attach the tape connector to the float.
8. Connect the grounding cable (A) to the float (point C).
Connecting the Cable to a Float in a Floatwell
Note Ensure you have completed all previous steps from your installation checklist
before proceeding.
Note On (internal or external) floating pan installations one end of the tape is connected
to a cable.
Float
Tape
Tape connector
Locking Tube
Clamp screw
2 required
Tape Clamp
2 required
Gauging Tape formed into "U"
Avoid bending at hole
6.00 Inch [155] piece of tape
formed into a "U"
Avoid bending at hole.
Grounding Cable
Float Grounding Clamp
3
Float
Tape
Cable
with ground connector
without ground connector
Cable Clamp
Tape Grounding Clamp
B
A
C
4

Table of Contents