Varec, Inc. 49
That section gives instructions to reset and calibrate the counter, install transmitters
and other auxiliary equipment, and replace the back cover.
Note Torque back cover bolts to 6 ft-lb. Do not over torque!
19. Refill gauge head with oil if required.
20. Close the tank inspection hatches and manholes.
Oil Seal Installation
For tank configurations that include optional oil seal accessories, refer to these illustrations
and perform the installation procedures included in this section.
For most installation, use a low-pour-point, food grade, water-white, mineral oil. Examples are
provided in section , Lubrication, on page 71.