Framing: Options are PCM31, PCM31C, PCM30, and PCM30C per G.704 and G.706 recommendations same as E1 described
above.
Note: Unframed signal types are not supported in the Nx64 fractional mode because framing is required to determine the location
of timeslots.
Unused: AIS, Broadcast, Unequipped used to fill up the unused (idle) timeslots
Timeslot Selection: Select the timeslot by tapping the applicable box. Deselect the timeslot by tapping the box again.
Note: Timeslots 1-31 correspond to channels 1-31 when using PCM-31 framing. When using PCM-30 framing, timeslots 1-15
correspond to channels 1-15, while timeslots 17-31 correspond to channels 16-30. Timeslot 16 is used for the Multi Frame
Alignment Signal.
Go back to top Go back to ToC
18.1.4 Pattern
Tap on the pattern box to access this feature. The test patterns can be applied to all PDH/DSn rates; however, ITU-T
recommends certain sequences dependent on the bit rate under test.
Coupled Pattern
Pattern: Use the pattern drop down box to select the test pattern which will be inserted into the transmitted signal. Pseudo
Random Bit Sequences (PRBS) defined by ITU-T 0.150 and 0.151 standards, fixed words and 24-bit or 32 bit user defined
patterns are available.
Note: If the 32 bit user pattern entered is incorrect, the default pattern will be 0xFFFFFFFF.
Invert: Inversion of polarity is available.
Out of Service (Rx only): Should be selected if the incoming signal is expected to contain a known test pattern. Deselect this
option if signal is expected to contain live network traffic, this will disable the pattern detection process and will enable the
reporting of LSS.
Note: ITU-T specification 0.150 recommends the following test patterns: