24.0 Additional Tests - Menu B
ISDN PRI CALL
Setup
Signal
Call-Voice Setup
Call - Data Setup
Data Call BERT Results
Supplementary Service Scan
Multi Call
DTMF
DBackup
ISDN PRI MONITOR
Clock Wander Analysis
Setup
Results
1PPS Phase Analysis
Setup
Result
Go back to top Go back to ToC
24.1 ISDN PRI Call
24.1.1 Setup (PRI Call Setup)
Configuration parameters for ISDN PRI Call are as follows:
(Page 1)
Mode: TE or NT
TE: Terminating Equipment used when the TX130M+ is emulating customer equipment. TE usually uses the
received signal to clock the transmitter.
NT: Network Terminal is used when the TX130M+ is emulating an ISDN switch, such as DMS-100, 5ESS. NT
usually uses the internal clock.
Monitor: Trace message details:
D Channel decodes help to verify that a call is successfully established, or determine why a call was not
completed by examining the protocol cause values.
Call Control: The Q.931 specification indicates which type of ISDN switch is to be tested.