EasyManua.ls Logo

Velodyne VLP-32C - Top:pwr_Raw; Top:pwr_Vccint; Bot:i_Out; Bot:lm20_Temp

Velodyne VLP-32C
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
pwr_3_3v = 2693
(raw value)
(2693 * 5.0) / 4096 = 3.287 V
10.2.3.3.6 top:pwr_raw
This is the top board's unregulated power rail. Its operating range is 1.6 V to 1.9 V.
To convert the raw value, use
Equation 10-1 on page 80
.
Example:
pwr_raw = 1428
(raw value)
(1428 * 5.0) / 4096 = 1.743
10.2.3.3.7 top:pwr_vccint
This is the top board's 1.2 V rail. Its operating range is 1.0 V to 1.4 V.
To convert the raw value, use
Equation 10-1 on page 80
.
Example:
pwr_vccint = 977
(raw value)
(977 * 5.0) / 4096 = 1.193 V
10.2.3.3.8 bot:i_out
This is the sensor's input power line. Its operating range is 0.3 A to 1.0 A. (It spikes whenever the motor spins up.)
To convert the raw value, use
Equation 10-2 on page 80
.
Example:
i_out = 2086
(raw value)
(2086 * 5.0) / 4096 = 2.546
10.0 * (2.546 - 2.5) = 0.464 A
10.2.3.3.9 bot:lm20_temp
This field indicates the temperature of the bottom board. Its operating range is -25.0° C to 90.0° C.
To convert the raw value, use
Equation 10-3 on page 80
.
Example:
lm20_temp = 1231
(raw value)
(1105 * 5.0) / 4096 = 1.503
-1481.96 + SQRT(2.1962E6 + ((1.8639 1.503) / 3.88E-6)) = 31.082° C