VI.BE.MAC.S.p.A.
pag.19
15.2.OUTPUTS
15.2.1. EXTERNAL JIG (04)
Connected to connector CON 8 (FU), in the card located on the right-hand side of the machine.
The two terminals used are 2 and the common to TE2 B5
It commands solenoid valve EV1 in the equipment of the machine.
15.2.2.INTERNAL JIG or LOADER JIG (0C)
Connected to connector TE2, in the card located on the right-hand side of the machine.
The two terminals used are A10 and the common to B7.
It commands solenoid valve EV2 in the equipment of the machine.
15.2.3.JIG RE-ENTRY or LOADER (08)
Connected to connector TE2, in the card located on the right-hand side of the machine.
The two terminals used are A6 and the common to B6.
It commands solenoid valve EV3 in the equipment of the machine.
It is called up on the programme using the function FUN1
15.2.4.UNLOADER (07)
Connected to connector TE2, in the card located on the right-hand side of the machine.
The two terminals used are A5 and the common to B4.
It commands solenoid valve EV4 in the equipment of the machine.
15.2.5.PRESSURE FOOT (05)
Connected to connector CON11 (PF), in the card located on the right-hand side of the machine.
The two terminals used are 3 and the common to 1.
It commands solenoid valve EV5 in the machine.
15.2.6.STACKER (02)
Connected to connector CON9 (W), in the card located on the right-hand side of the machine. The two
terminals used are 3 and the common to TE2 B5.
It commands solenoid valve EV6 in the equipment of the machine.
It is called up on the programme using the function FUN2