VI.BE.MAC.S.p.A.
pag.18
15. ELECTRICAL CONNECTION
15.1. INPUTS
There is a card on the right-hand side of the machine, with a series of terminals for the various connections.
15.1.1. LEFT GREY PEDAL (I1)
Connected to connector CON I, located in the back of the main cabinet
The two terminals used are n°1 and n°2.
Its function is:
- LABEL commands the INTERNAL Jig in the equipment of the machine
- DESIGN commands the start of the sewing cycle
- DESIGN with LOADER commands the Jig in the equipment of the machine.
15.1.2.RIGHT BLACK PEDAL (I2)
Connected to connector CON I, located in the back of the main cabinet.
The two terminals used are n°1 and n°3.
Its function is:
- LABEL commands the EXTERNAL Jig in the equipment of the machine
- DESIGN commands the Jig in the equipment of the machine
- DESIGN with LOADER commands the Material Blocking Jig in the loader unit.
15.1.3.LEFT YELLOW MICROSWITCH on the sewing head (IH)
Connected to connector TE2, in the card located on the right-hand side of the machine.
The two terminals used are B3 and common B10.
Its function is:
- LABEL commands the start of the sewing cycle
- DESIGN not used
- DESIGN with LOADER commands the start of the sewing cycle
15.1.4. RIGHT YELLOW MICROSWITCH on the sewing head (ID)
Connected to connector TE1, in the card located on the right-hand side of the machine
The two terminals used are A9 and common B10.
Its function is:
- LABEL and DESIGN not used
- DESIGN with LOADER commands the start of the loader
15.1.5. RED STOP MICROSWITCH on the sewing head (I4)
Connected to connector CON3, in the card located on the right-hand side of the machine.
The two terminals used are 1 and 2.
It stops the sewing cycle and blocks all movements of the sewing head. (STOP)
15.1.6. LOADER RIGHT LIMIT STOP MICROSWITCH (I7)
Connected to connector TE1, in the card located on the right-hand side of the machine
The two terminals used are A6 and the common A5.
It sends a signal to the software that the Loader has arrived in its standby position.
15.1.7. LOADER LEFT LIMIT STOP MICROSWITCH (IA)
Connected to connector TE1, in the card located on the right-hand side of the machine
The two terminals used are B4 and the common A5.
It sends a signal to the software that the Loader has arrived in its loading position.
15.1.8. BROKEN THREAD SENSOR (IG)
Connected to connector TE2, in the card located on the right-hand side of the machine.
The three terminals used are:
B2 (Red +) B1 (Brown Out) B10 (White -)
It sends a signal to the software that, for some reason, the thread inside is not flowing.
15.1.9. INTERNAL JIG RE-ENTRY SENSOR (IO)
Connected to connector G, located on the back of the main cabinet. The three terminals used are n°1
(LIGHT BLUE), n°9 (out BLACK) and n°25 (+ BROWN). It sends a signal to the software reporting the
position of the internal jig after reading the code FUN1.