VI.BE.MAC.S.p.A.
pag.29
Press the down arrow key
The following appears on the display:
BU.302 Version of BIOS in use in the main memory
Press the down arrow key
The following appears on the display:
SU.459 Version of system SOFTWARE in use in the main memory
Press the H key to exit
20.4. MATERIAL CARRIAGE PARAMETER CONTROL – TENSION RELEASE TIME DURING CUT
CYCLE
On the command console fixed to the card cabinet under the Loader:
Press the F key
The following appears on the display:
F U N C
Press the down arrow and the B key together
The following appears on the display:
P - b (B mode)
Hold the two keys down until the display changes to:
W b t. o f
Press the down arrow key until the following appears on the display:
S 8. 0 9 4 (Alternated Feed of the Material – material shift start value)
The parameter S 8. can be adjusted between the value of 084 and 104 in the event of problems. Standard
Value = 94.
Press the down arrow key until the following appears on the display:
L 1. 240 (Tension release delay)
Use the D key to change the units
Use the C key to change the tens
Use the B key to change the hundreds
Use the A key to change the thousands
The parameter L1. can be adjusted between the value of 040 and 240
Press the H key to exit