5. PROGRAMMING
D-303222 PowerMaster-10/30 G2 Installer's Guide 41
45:STROBE TIME
Define the length of time the strobe light will flash upon alarm.
Options: 5/10/20 (default)/40/60 minutes.
46:SIREN ON LINE
Determine if the siren will be activated when the phone line fails and the system is armed.
Options: disable on fail (default) or enable on fail.
5.5.6 Configuring Audible & Visual User Interface
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration refer to section 5.5.1.
Option
Configuration Instructions
51:PIEZO BEEPS
With Partition disabled
Define whether the panel will sound the exit/entry warning beeps during exit and entry delays or
not. An additional option is to mute the warning beeps only when the system is armed “HOME”.
Options: ON (default), OFF when home (default in USA) and OFF, and OFF exit home.
Note: When exit beeps are OFF, the happy (success) melody will still sound toward the end of
an exit delay.
The volume level of the exit / entry beeps can be modified by pressing the button on
the keypad to increase the volume, or by pressing the button to decrease the volume.
51:PIEZO BEEPS
With Partition enabled
Define whether the panel will sound the exit/entry warning beeps during exit and entry delays or
not. An additional option is to mute the warning beeps only when the system is armed “HOME”.
The control panel’s display is: Def:P1 P2 P3
The pushbuttons , , and provide selection of the corresponding partitions.
Pressing each button repeatedly will toggle between each option.
Options: (enable beeps), H (OFF when home) h (OFF exit home) and
(disable beeps).
Notes:
When exit beeps are OFF, the happy (success) melody will still sound toward the end of an
exit delay.
The volume level of the exit / entry beeps can be modified by pressing the button on
the keypad to increase the volume, or by pressing the button to decrease the volume.
52:TROUBLE BEEPS
Under trouble conditions, the panel sounder emits a series of 3 short reminder beeps once per
minute. Define whether to enable or disable this reminder beeping or just disable it at night.
The “night” hours are defined in the factory but are usually from 8 PM (20:00) until 7:00 AM.
Options: ON (default in USA); OFF at night (default) and OFF.
Note: Audible trouble beeps to be enabled for UL Listed product.
53:MEMORY PROMPT
Define whether or not the user will receive "Memory" LCD indication that an alarm has been
activated. By pressing the button in standby mode, you can view details of the alarm
memory.
Options: ON (default) and OFF.
Note: For UL installations, set to “ON”.
54:LOW-BAT ACK
You can activate or deactivate the "Low Battery Acknowledge" requirement from the user whose
keyfob's battery is low. For further information, see PowerMaster User's Guide Chapter 5.
Options: OFF (default) acknowledge not needed; ON acknowledge required.
Note: For UL installations, Low Battery Acknowledge must be set to ”ON".
55:BACK LIGHT
Define whether the panel's back lighting will remain on at all times or will turn on only when a
key is pressed and turn off within 10 seconds if no further keystrokes are sensed.
Options: always ON and OFF after 10 sec (default).

Table of Contents

Other manuals for Visonic PowerMaster-10 G2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic PowerMaster-10 G2 and is the answer not in the manual?

Visonic PowerMaster-10 G2 Specifications

General IconGeneral
ModelPowerMaster-10 G2
CategorySecurity System
Wireless TechnologyPowerG
Remote ControlYes
Event Log1000 events
CommunicationGSM, PSTN, IP
Frequency868 MHz
TypeWireless
Operating Temperature-10°C to +55°C
HumidityUp to 85% non-condensing