5. PROGRAMMING
D-303222 PowerMaster-10/30 G2 Installer's Guide 61
Option
Configuration Instructions
06:CONFIRM PANIC
A confirmed panic alarm is reported if one of the following occurs within the confirmation time:
a) A second panic device is activated.
b) A second panic alarm on the same device is activated.
c) A tamper event is activated (not from the zone / device that initiated the panic alarm).
Options: 4/8/12/20 (default)/24 hours and disabled
07:RPT CNFM ALRM
Define whether the system will report a confirmed alarm.
enable + bypass (default) - The system will report a confirmed alarm and will bypass all
alarmed open zones when the siren ends or when the confirmation timer expires.
disable - The system will not report a confirmed alarm.
enable - The system will report a confirmed alarm.
08:ENTRY DELAY 1
09:ENTRY DELAY 2
Two different entry delays allow the user to enter the protected site (while the system is in the
armed state) via 2 specific doors and routes without causing an alarm.
Following entry, the user must disarm the control panel before the entry delay expires. Slow-
rate warning beeps start sounding once the door is opened, until the last 10 seconds of the
delay, during which the beeping rate increases. Locations No. 1 (entry delay 1) and 2 (entry
delay 2) allow you to program the length of these delays.
Options: 10/15/30 (ENTRY DELAY 1 default)/45/60 (ENTRY DELAY 2 default) seconds;
3/4 minutes
5.15.4 DD243 Setup
13:OPERATION MOD
03:DD243 SETUP
Enter the "03:DD243 SETUP" menu, and press to configure DD243 compliance standard settings.
Option
Configuration Instructions
01:DISARM OPTION
Define when it is possible to disarm the system:
entry/wl+awy kp By the control panel when the system is armed AWAY. By keyfob or
keyprox during entry delay only.
entry/all devs - During entry delay, when the system is armed AWAY, by all devices. When
not in entry delay by keyfob or keyprox only.
entry/DD devs (default) - During entry delay, when the system is armed AWAY, by using the
keyfob or keyprox. Keypads cannot disarm at all.
anytime/all dev At any time and by all devices.
02:ENTRY ALARM
Define whether the system will report a confirmed alarm during an entry delay (see CONFIRM
ALARM below).
DD243 (default) - An alarm initiated by another detector during the entry delay is not regarded
as a confirmed alarm.
EN standard - The control panel will report a confirmed alarm for the second alarm that is
triggered from a different zone within the confirmation time. There are no alarm restrictions
during entry delay or for the delay zone.
03:END EXIT MODE
Define how the exit delay is terminated or restarted according to the following options:
door/fob only - When the door is closed, or by pressing the AUX button on the keyfob
1
,
whichever first.
restart>reentry - Exit delay restarts when the door is reopened during exit delay. The restart
occurs once only. Restarting the exit delay is helpful if the user re-enters immediately after
going out to retrieve an item that was left behind.
door/fob/timer - When the door is closed, by pressing the AUX button on the keyfob
1
, or when
the exit delay has expired, whichever first.
fob/timer (default) - By pressing the AUX button on the keyfob
1
, or when the exit delay has
expired, whichever first.
1
Applies only when the keyfob is defined as "skip exit delay" (for further details, see the keyfob's User's Guide)

Table of Contents

Other manuals for Visonic PowerMaster-10 G2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic PowerMaster-10 G2 and is the answer not in the manual?

Visonic PowerMaster-10 G2 Specifications

General IconGeneral
ModelPowerMaster-10 G2
CategorySecurity System
Wireless TechnologyPowerG
Remote ControlYes
Event Log1000 events
CommunicationGSM, PSTN, IP
Frequency868 MHz
TypeWireless
Operating Temperature-10°C to +55°C
HumidityUp to 85% non-condensing

Related product manuals