5. PROGRAMMING
D-303222 PowerMaster-10/30 G2 Installer's Guide 43
Options: after 1/2/4/8/12 (default) hour(s); and disabled.
Notes:
1. To comply with EN requirements, 1 hour or 2 hours must be selected.
2. For UL installations, set to “4 hours” or less.
3. For UL/ULC Residential Fire and Burglary Installations, the wireless supervision window
shall be enabled. It shall be set to 4 hours or less for Fire Installations and it shall be set to
24h for Burglary Installations only.
Define that in case of a supervision problem (i.e. a device is "missing" - see "62: MISSING
REPRT") whether the system will continue to operate as normal or the system status will
become "Not Ready" (upon missing) for as long as the "Missing" trouble exists.
Options: normal (default) and if missing dev.
64:MISS/JAM ALRM
Previously known as
"BELL/REP.OPT"
"EN/UL standards" require that if a supervision (missing) or jamming trouble occurs during
AWAY arming, the siren will sound and the event will be reported as a tamper event.
Define whether the system will behave according to EN standards or as normal (default).
Note: To comply with EN requirements "EN standard" must be selected.
5.5.8 Configuring Miscellaneous Features
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 5.5.1.
Configuration Instructions
User Permission enables you to determine whether access to the INSTALLER MODE requires
the user's permission or not. If you select enabled, the installer will be able to access the system
only through the user menu after the user code has been entered (see section 5.2).
Options: disable (default) or enable (default in UK).
Note: To comply with EN requirements, "Enable" must be selected.
Define which type of battery pack is used for the system to supply proper charge current.
Options: 7.2V NiMH (default) or 9.6V NiMH (default in UK).
5.6 Communication
5.6.1 General Guidance – "Communication" Flow-Chart & Menu Options
The COMMUNICATION menu enables you to configure and customize the communication and reporting of alarm,
troubles and other system events for monitoring companies or private users according to your local requirements and
personal preferences. PowerMaster offers a variety of communication means including telephone PSTN landline,
Cellular GSM, GPRS or SMS and IP via broadband internet connection.
Notes:
1. GPRS cannot be enabled in UL Listed product.
2. SMS is a supplementary feature.
The "04.COMMUNICATION" menu contains several sub-menu options, each covering a group of configurable features
and parameters related to the communication and reporting as follows (see detailed list in Step 3 of the chart below):
Description of Option Features and Parameters
Contains configurable features and parameters related to the PSTN telephone line
to which the PowerMaster is connected.
Contains configurable features and parameters related to the Cellular connection
of the PowerMaster system.
Contains configurable features and parameters related to Reporting of event
messages to Monitoring Stations via telephone, cellular or IP broadband
communication.
Contains configurable features and parameters related to Reporting event
messages to Private Users via telephone or SMS.
Refers to PowerMaster-30 G2 only