5. PROGRAMMING
46 D-303222 PowerMaster-10/30 G2 Installer's Guide
SIM PIN CODE
Enter the PIN code of the SIM card installed in the GSM module (up to 8 numerical digits).
Note: To enter the numerical PIN code, use the numerical keyboard.
GPRS PASSWORD
Enter the Password of the APN used for GPRS communications (up to 16 digits string).
Note: To enter the Password, use the "String Editor" at the end of this section.
NETWORK ROAMING
Previously known as
"FORCE HOME NTWK"
You can force the SIM card to use only its "Home Network" and disable it from roaming to
other networks in case the Home Network cannot be found.
Options: roam disable; roam enable (default).
GPRS ALWAYS ON
Previously known as
"SESSION TIMEOUT"
Define whether the control panel will stay continuously connected "enabled", via GPRS
communication, or disconnect "disabled" (default), after each report session.
Note: For UL installations, set to enabled”.
GSM KEEP ALIVE
Some GSM Service providers tend to disconnect the GSM connection if the user has not
initiated any outgoing telephone calls during the last 28 days. To prevent from disconnecting
the GSM connection, you can configure the system to generate a "keep alive" GSM call
every 28 days sending a test message either to the first SMS number (if exists) or
alternatively first private telephone number.
Options: Disable (default) or Every 28 days.
TRANS. PROTOCOL
Select the IP protocol used to transfer data over the internet/GPRS.
Options: TCP (default); or UDP.
PowerMaster String Editor
Key
String Editor Functionality
Moves the digits cursor from left to right. Long press for fast movement.
Moves the digits cursor from right to left. Long press for fast movement.
Places digits cursor to the extreme right position of edit string and shows the last 16 digits of string.
Scrolls upward the alphanumerical/symbols sequence of inserted digits. Long press for fast scroll.
For the sequence of the digits, see end of this table.
Scrolls downward the alphanumerical/symbols sequence of inserted digits. Long press for fast scroll.
For the sequence of the digits see end of this table.
Changes between lowercase letters (a,b,c…z) and uppercase letters (A,B,C…Z).
Clears a single digit of the string by cursor.
Clears all digits of the string to the right of cursor.
Confirms and saves the edited string and reverts to previous menu.
Exiting the edit screen and moves one level up to previous or top menu without saving the edit string.
Exiting the edit screen and moves to the "<OK> TO EXIT" exit screen without saving the edit string.
Sequence
Alphanumeric/symbol sequence: a/A, b/B….z/Z; 0,1,2…9; ! # % & ' * + - / = ^ @ . _ ?

Table of Contents

Other manuals for Visonic PowerMaster-10 G2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic PowerMaster-10 G2 and is the answer not in the manual?

Visonic PowerMaster-10 G2 Specifications

General IconGeneral
ModelPowerMaster-10 G2
CategorySecurity System
Wireless TechnologyPowerG
Remote ControlYes
Event Log1000 events
CommunicationGSM, PSTN, IP
Frequency868 MHz
TypeWireless
Operating Temperature-10°C to +55°C
HumidityUp to 85% non-condensing

Related product manuals