1. INTRODUCTION
D-303222 PowerMaster-10/30 G2 Installer's Guide 5
Wired zones and
programmable
outputs (PGM)
The control panel can support wired detectors
and control automation devices with
programmable wired outputs.
1. Connect a wired zone or PGM device:
see section 3.6 Adding a Wired Zone or
PGM.
2. Program the wired zone: see section
5.4.2 Adding New Wireless Devices or Wired
Sensors
3. Program PGM outputs behavior: see
section 5.7 PGM Output.
Reporting to Private
Users and/or
Monitoring Station by
telephone, SMS and
IP communication
The PowerMaster system can be
programmed to send notifications of alarm
and other events to 4 private telephone
subscribers by voice and also to 4 SMS
cellular phone numbers and to report these
events to the Monitoring Station by SMS,
PSTN or IP communication
(IP communication not enabled in UL Listed
product).
To configure notifications to Private
phones: refer to the PowerMaster-10/30 G2
User's Guide, Chapter 6, section C.11
Programming Private Phone and SMS
Reporting
To configure reporting to the Montioring
Station: see section 5.6.4 Configuring
Events Reporting to Monitoring Stations
Quick installation with
link quality indication
With PowerG devices, there is no need to
consult the control panel when mounting a
wireless device, because PowerG devices
include a built-in link quality indicator.
Choosing the mounting location is a quick
and easy process.
To choose the ideal location to mount a
wireless device, see Chapter 2 Choosing the
Installation Location.
Helps you to easily identify the actual device
displayed on the LCD display.
To read more on the Device Locator: refer
to the PowerMaster-10/30 G2 User's Guide,
Chapter 2, Operating the PowerMaster
System
To use the device locator when bypassing
a zone or when clearing a bypassed zone:
refer to the PowerMaster-10/30 G2 User's
Guide, Chapter 6, section C.1 Setting the
Zone Bypass Scheme
To use the device locator when
conducting the periodic test: see Chapter
6 Periodic Test or refer to the PowerMaster-
10/30 G2 User's Guide, Chapter 9 Testing
the System
PowerMaster is able to control a safe that
holds site keys that are accessible only to the
site's guard or Monitoring Station's guard in
the event of an alarm.
1. Connect the safe to the panel: see
section 3.6 Adding Wired Zones or PGM
Device, Figure 3.6b (PowerMaster-10 G2) /
section 4.7 Optional Expander Module
Mounting, Figure 4.8b (PowerMaster-30 G2)
2. Configure the safe's zone type to
"Guard Zone": see section 5.4.2 Adding
New Wireless Devices or Wired Sensors
3. Setup guard code: see section 5.3
Setting Installer Codes
External system may control arming and
disarming of the PowerMaster system
1. Connect the external system output to
the panel: see section 3.6 Adding Wired
Zones or PGM Device, Figure 3.6b
(PowerMaster-10 G2) / section 4.7 Optional
Expander Module Mounting, Figure 4.8b
(PowerMaster-30 G2)
Note: Monitoring Station means not evaluated by UL.