To Configure Permissions for System Reset after an Alarm Event
1.
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
2.
3.
4.
or
5.
Select between "user reset" (default), "engineer reset" and "anti
code reset".
You can now press the or button to program any other menu
in "
DEFINE PANEL
" or press the button to take you to "
<OK> TO EXIT
".
4.4.6 Configuring a Duress Code
A duress alarm (ambush) message can be sent to the Monitoring Station if the user is forced to disarm the system
under violence or menace. To initiate a duress message, the user must disarm the system with the duress code
(2580 by default). Here you can change the code digits or enter "0000" to disable the duress feature. The system
does not allow the user to program the duress code saved in this memory location as an existing user
code.
Note: Duress Code is not applicable in the UK.
To Configure a Duress Code
1.
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
2.
3.
4.
or
5.
Change the code or enter 0000 to disable the duress function.
You can now press the or button to program any other menu in
"
DEFINE PANEL
" or press the button to take you to "
<OK> TO EXIT
".
0
1:ENTRY DELAY 1
2
5:RESET OPTION
2
3:DURESS
D
URESS CODE 2580
2
3:DURESS
0
1:ENTRY DELAY 1
DEFINE PANEL
2
5:RESET OPTION
u
ser reset
DEFINE PANEL

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMASTER-10 - INSTALLER GUIDE and is the answer not in the manual?

Visonic POWERMASTER-10 - INSTALLER GUIDE Specifications

General IconGeneral
CategorySecurity System
ModelPOWERMASTER-10
Wireless ProtocolPowerG
Backup BatteryYes
User CodesUp to 48 user codes
TypeWireless Alarm System
Partitions3
CommunicationGSM
Wireless Frequency868 MHz
KeypadsUp to 8 keypads
Event Log1000 events
Power SupplyExternal power supply
Backup Battery Voltage7.2V
Operating Temperature-10°C to +50°C
Humidity85% non-condensing
ZonesUp to 30 wireless zones

Related product manuals