22 D-302756
7.
8.
The device is deleted from the PowerMaster-10 system.
When exiting "ZONES / DEVICES" menu the PowerMaster-10 system
displays the number of devices that need to be updated, as follows: DEV
UPDATING NNN.
You can now press the button to delete the device of the same
type, or press the button to delete a different device, or press the
button to take you to "
<OK> TO EXIT
".
4.5.5 Modifying a Device
D. To Modify a Device
Note: This procedure is applicable to detectors only.
1.
Repeat steps 1 to 3 in section 4.5.2 "Adding a Wireless Device".
2.
or
3.
Select the desired sensor to be modified. Select between "CONTACT
SENSORS", "MOTION SENSORS", "SMOKE SENSORS" and "WIRED
SENSORS", for example, "MOTION SENSORS".
4.
or
5.
6.
The PowerMaster-10 display will read "Front door".
7.
or
Select a location, or, enter the location number, for example,
"Master Bdrm".
8.
9.
10
or
Select a zone type, or, enter the zone type number, for example,
pressing 03 selects "3. Home Delay".
To understand the behavior of each zone, see section 4.5.2.3 Zone
Types.
3. Home Delay
12.Non-Alarm
Z01:ZONE TYPE
Master Bdrm
Front door
Z01:LOCATION
Z01:Motions Sens
CONTACT SENSORS
MODIFY DEVICES
ADD NEW DEVICES
MOTION SENSORS
(OFF) to delete

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMASTER-10 - INSTALLER GUIDE and is the answer not in the manual?

Visonic POWERMASTER-10 - INSTALLER GUIDE Specifications

General IconGeneral
CategorySecurity System
ModelPOWERMASTER-10
Wireless ProtocolPowerG
Backup BatteryYes
User CodesUp to 48 user codes
TypeWireless Alarm System
Partitions3
CommunicationGSM
Wireless Frequency868 MHz
KeypadsUp to 8 keypads
Event Log1000 events
Power SupplyExternal power supply
Backup Battery Voltage7.2V
Operating Temperature-10°C to +50°C
Humidity85% non-condensing
ZonesUp to 30 wireless zones

Related product manuals